Specification sheet · VTC series (Vibration Thermal Chamber)

VTC-9 ECO HALT/HASS Chamber

Combined thermal and six-degree-of-freedom vibration chamber for HALT and HASS, with a 36 × 36 in vibration table. Designed, built and supported in Allegan, Michigan.

Hanse VTC-9 HALT/HASS chamber with its front door open, showing the vibration table and the workspace
†Photo shows the VTC-9.
vibration table
36 × 36 in
temperature range
−100 to +200 °C
product change rate*
70 °C/min
6-DoF repetitive shock
10–10,000 Hz
maximum vibration level
100 GRMS
maximum load
700 lb

Thermal performance

Temperature range
−100 to +200 °C
Product change rate*
70 °C/min, −65 to +100 °C
Temperature control
±1 °C after stabilization; stabilization in under 2 minutes
Cooling
HighRate™ liquid nitrogen, direct atomization in the control plenum, proportional control
Heating
99 kW nichrome wire heaters, zero-cross SCR control
Thermocouples
One for air (control), one for product response

Vibration

Type
Tri-axial 6-DoF repetitive shock, non-coherent broadband, 10–10,000 Hz
Vibration level
Up to 100 GRMS, unloaded table at 25–30 °C
Energy distribution
90% of vibration energy in 10–4,000 Hz
Repeatability
±1 GRMS 1 min after settling, from 5 to 75 GRMS
Sound level
At 10 GRMS, nominally 68 dBA at 1 m
Vibration table
36 × 36 in (914 × 914 mm), ceramic-coated and insulated from its base
Mounting inserts
Stainless steel, 3/8-16 on a 4 × 4 in pattern or M10 on a 100 × 100 mm pattern
Maximum load
700 lb (318 kg)
Vibrators
Pneumatic, LubeMist™ lubricated with an adjustable ball valve on each; SoftStart™ to minimize starting shock

Chamber

Interior (W × D × H)
42 × 42 × 38 in (1,067 × 1,067 × 965 mm)
Exterior (W × D × H)
68.25 × 61 × 98 in (1,734 × 1,549 × 2,489 mm)
Weight
4,000 lb (1,814 kg)
Doors
Two manual doors: one front, one rear
Windows
Two heated multi-pane windows, 20 × 20 in, one in each door
Ports
Three 6 in and two 1 in ports for customer use
Insulation
Multilayer staggered insulation, for thermal and noise insulation

Utilities

Electrical
480 V, 3-phase, 125 FLA
Liquid nitrogen
1/2 in supply, 40–50 psig
Compressed air
1 in supply, 120 psig (8.3 bar), 120 SCFM, clean and dry
Exhaust
Two 6 in exhaust ports, vented to outside
Installation
Unloading, rigging and utility connections are provided by the customer

Control and instrumentation

Control
Watlow controller with Hanse ChamberCore software: temperature, humidity and GRMS ramps in one profile over Ethernet
ChamberDAQ
24 universal inputs on each Watlow F4T (thermocouple, RTD, mA, mV/V), with more F4Ts for more inputs, plus up to eight WebDAQ modules for 128 external thermocouple channels
ChamberFFT (option)
Vibration analysis on up to 16 IEPE accelerometer channels at 25,600 samples per second
Accelerometer
One accelerometer with cable and three-axis mounting block

Safety

Door interlocks
Opening a door shuts off system operation
Emergency power off
EPO shuts off system operation
Over/under limit
FM-approved, with its own sensor in the air stream
Interlocks
Heaters and LN2 interlocked to the fans; three-phase supply monitored for phase loss and balance
Electrical code
Built to NEC code with UL / CE marked components

Options

  • Extended temperature — down to −150 °C and up to +400 °C, as an option or custom build.
  • Humidity — direct water injection or a steam generator, 10 to 85% RH from 25 to 65 °C, with a capacitance sensor.
  • Fixtures — designed for your assembly, with metric or inch hole patterns.
  • More channels — specify at order; channels are far cheaper than a retrofit.
  • Access ports — extra ports, 6 in or custom sizes, for cabling and powered functional test.
  • Higher load capacity — available across the range.
  • LN2 system — complete installation, piping and controls.

Warranty and support

  • 3-year warranty on vibrators and vibration tables.
  • 1-year equipment warranty from shipment: parts and labor for the first 90 days, then parts at no cost other than travel.
  • Supported for the long term — including controller retrofits for older systems.