Specification sheet · TC series (Thermal Chamber)

TC-25 Thermal Chamber

Liquid-nitrogen cooled thermal chamber for fast temperature cycling and thermal screening without vibration, with a 66 × 66 × 66 in (1,676 × 1,676 × 1,676 mm) interior: the width and depth of the VTC-25. Designed, built and supported in Allegan, Michigan.

Hanse VTC-32 environmental test chamber with its doors closed
†Photo shows the VTC-32.
interior (W × D × H)
66 × 66 × 66 in (1,676 × 1,676 × 1,676 mm)
temperature range
−100 to +200 °C
product change rate*
70 °C/min
heaters
133 kW
weight
5,000 lb (2,268 kg)

Thermal performance

Temperature range
−100 to +200 °C
Product change rate*
70 °C/min, −65 to +100 °C
Temperature control
±1 °C after stabilization; stabilization in under 2 minutes
Cooling
Liquid nitrogen, direct atomization in the control plenum, with a redundant safety valve
Heating
133 kW balanced nichrome wire heaters, zero-cross SCR control
Air flow
Adjustable plenum: multiple 3 in ports on each side direct the airflow onto the product
Thermocouples
Two Type T: one in the control air, one for product response

Chamber

Interior (W × D × H)
66 × 66 × 66 in (1,676 × 1,676 × 1,676 mm)
Exterior (W × D × H)
96 × 79 × 107 in (2,438 × 2,007 × 2,718 mm)
Doors
Two bi-parting, front and back
Windows
Four, 12 × 24 in (305 × 610 mm), tempered multi-pane
Lights
Three, adjustable
Ports
Three 6 in for customer use
Insulation
Multilayer staggered insulation, for thermal and noise insulation
Sound level
65 dBA nominal at 1 m
Weight
5,000 lb (2,268 kg)

Utilities

Electrical
480 V, 3-phase, 170 FLA
Liquid nitrogen
1 in supply, 40–50 psig (2.8–3.4 bar)
Compressed air
3/4 in, 120 psig (8.3 bar), 45 SCFM (76 m³/h), clean and dry
Exhaust
Four 6 in exhaust ports, vented to outside
Installation
Unloading, rigging and utility connections are provided by the customer

Control and instrumentation

Control
Watlow F4T controller with Hanse ChamberCore software: programmable temperature ramps and closed-loop cascade control of the product temperature, over Ethernet
ChamberDAQ
24 universal inputs on each Watlow F4T (thermocouple, RTD, mA, mV/V), with more F4Ts for more inputs, plus up to eight WebDAQ modules for 128 external thermocouple channels

Safety

Door interlocks
Opening a door shuts off system operation
Emergency power off
EPO shuts off system operation
Over/under limit
FM-approved, with its own sensor in the air stream
Interlocks
Heaters and LN2 interlocked to the fans; three-phase supply monitored for phase loss and balance
Electrical code
Built to NEC code with UL / CE marked components

Options

  • Extended temperature — down to −150 °C and up to +400 °C, as an option or custom build.
  • Humidity — direct water injection, 10 to 85% RH from 25 to 65 °C, with a capacitance sensor.
  • More thermocouples — 14 more, for 16 monitored in all.
  • Floor plug — an insulated plug that reduces the working volume.
  • Anti-condensate heaters — for the door, windows and outer surfaces.
  • LN2 system — complete installation, piping and controls.
  • Vibration — add a standalone 6-DoF vibration table, or choose the VTC-25 HALT/HASS chamber.

Warranty and support

  • 1-year equipment warranty from shipment: parts and labor for the first 90 days, then parts at no cost other than travel.
  • Supported for the long term — including controller retrofits for older systems.
  • Built in Allegan, Michigan — designed, fabricated and supported in the US since 1993.